当前位置:首页 > 过刊浏览->2026年第52卷第5期
组合式移动应急油库拦油池设计
Design of combined mobile emergency oil depot oil containment pools
浏览(4) 下载(0)
- DOI:
- 作者:
- 左永刚,孙文杰,葛开颜,刘越豪
Zuo Yonggang, Sun Wenjie, Ge Kaiyan, Liu Yuehao
- 作者单位:
- 联勤保障部队工程大学,重庆 401331
Engineering University of the Joint Logistics Support Force, PLA, Chongqing 401331, China
- 关键词:
- 油气田地面工程;组合式拦油池;软体储罐;模块化设计;溢油防治
oil and gas field surface engineering; combined oil containment pool; flexible storage tank; modular design; oil spill containment
- 摘要:
- 软体储罐凭借其轻便灵活的优势被广泛应用于野外临时储油场景,但受罐体壁薄、结构强度低等因素
制约,泄漏溢油风险较高,需配套构筑拦油池作为二次防护设施。传统土方、沙袋式拦油池存在地形适应性
差、构筑效率低、材料阻燃性能不足,以及功能单一等技术局限,本文设计开发了一种模块化轻便型组合式拦
油池。该装置采用L形拦油板卡扣卡口拼装结构,无需专用工具,运输部署便捷。拦油板采用ABS增强阻燃材
料,兼具轻量化特征与阻燃安全性,集成排水功能模块与可拆卸式撑管桥,实现溢油围控、积水排放及输油胶
管保护一体化。针对400 m³规格拦油直板开展有限元仿真,结果表明:静态工况下最大应力为10.27 MPa,远
低于材料弯曲强度(66.5 MPa);瞬态冲击工况下最大应力39.9 MPa,以弯曲强度为基准计算安全系数1.67,
满足规范要求,但安全裕度有限。样机测试验证了该装置布设高效、场地适配性强,可为油气田野外溢油应急
防护提供可靠技术方案。
Flexible storage tanks are widely applied to temporary oil storage in field environments owing to their lightweight and flexible nature. However, due to limitations such as thin tank walls and low structural strength, these tanks have a relatively high risk of oil leakage or spillage. Therefore, auxiliary oil containment pools should be constructed as secondary protection facilities. Traditional earthwork-based or sandbag-based oil containment pools suffer from technical limitations including poor terrain adaptability, low construction efficiency, inadequate flame-retardant material performance, and limited functionality. This paper develops a lightweight combined oil containment pool. The device employs an L-shaped modular oil containment panel assembly structure and requires no specialized tools, facilitating easy transportation and deployment. The oil containment panels are fabricated from reinforced ABS flame retardant material, combining lightweight design with flame-retardant safety. Meanwhile, a drainage function module and a detachable support pipe bridge are integrated to provide an integrated solution for oil spill containment, water drainage, and hose protection. Finite element simulations are conducted on a 400 m³-sized straight oil containment panel. The results indicate that in static loading conditions, the maximum stress is 10.27 MPa, which is far lower than the material’s bending strength of 66.5 MPa. In transient impact loading conditions, the maximum stress is 39.9 MPa with a safety factor of 1.67, complying with regulatory requirements while leaving a limited safety margin. Prototype testing verifies the device’s high deployment efficiency and strong site adaptability, which can provide a reliable technical solution for emergency oil spill protection in oil and gas field operations.