油田联合站综合能源系统优化调度分析与研究
Optimal scheduling of integrated energy system for oilfield joint station
浏览(3) 下载(0)
- DOI:
- 作者:
- 王君妍,王充,李小刚,冯小梅,张凯,梁昌晶
Wang Junyan1, Wang Chong, Li Xiaogang, Feng Xiaomei, Zhang Kai, Liang Changjing
- 作者单位:
- 1. 中国石油华北油田公司第一采油厂,河北任丘 062552; 2. 中国石油华北油田公司第五采油厂,河北辛集 052300; 3. 昆仑能源有限公司华港燃气集团有限公司,河北廊坊 065000
1. The First Oil Production Factory of Huabei Oilfield Company, PetroChina, Renqiu 062552, China; 2. The Fifth Oil Production Factory of Huabei Oilfield Company, PetroChina, Xinji 052300, China; 3. Kunlun Energy Company Limited, Huagang Gas Group Co., Ltd., Langfang 065000, China
- 关键词:
- 联合站;综合能源系统;风电;光伏;电转气;碳捕集与封存
joint station; integrated energy system; wind power; photovoltaic; power-to-gas; carbon capture and storage
- 摘要:
- 油田联合站的传统用能模式高度依赖外购电与伴生气直燃,普遍存在能源利用率低、碳排放量高等问
题。构建融合风电、光伏、储能、电转气(P2G)及碳捕集与封存(CCS)的电-热-冷-气耦合综合能源系
统,以某油田联合站为研究对象,建立了包含外购能源、运行维护、碳交易、碳封存及新能源弃用惩罚的优化
调度模型,对多种场景与极端工况展开对比仿真分析。结果表明:与传统场景、新能源场景和碳减排场景相
比,综合能源场景的日运行成本分别降低了62.2%、42.7%、58.6%,有效促进了新能源就地消纳与CO₂捕集
和资源化利用;CHP机组、燃气锅炉、电制冷、P2G、CCS设备的平均负荷率分别为80.2%、56.1%、
55.4%、56.2%、60.9%,各设备均具备充足调节裕度,可应对负荷波动;三种极端工况下的仿真结果显示,
CHP机组是保障系统经济低碳运行的核心设备,储能单元可有效平抑源荷波动,储气单元可在气源供应中断时
提供应急保供能力。研究结果可为油田联合站用能结构的转型提供技术支撑。
The traditional energy consumption mode of oilfield joint stations relies heavily on purchased electricity and direct combustion of associated gas, resulting in low energy utilization efficiency and high carbon emissions. To address these issues, this paper develops a coupled integrated electricity-heat-cooling-gas energy system incorporating wind power, photovoltaic power, energy storage, power-to gas (P2G), and carbon capture and storage (CCS).Taking a certain oilfield joint station as the research object, an optimal scheduling model is built that includes purchased energy, operation and maintenance, carbon trading, carbon sequestration, and penalties for renewable energy curtailment. Comparative simulation analyses are conducted under multiple scenarios and extreme conditions. The results show that, compared with the traditional scenario, the renewable energy scenario, and the carbon reduction scenario, the daily operating cost of the integrated energy scenario is reduced by 62.2%, 42.7%, and 58.6%, respectively, effectively promoting the local consumption of renewable energy and the capture and resource utilization of CO₂. The average load rates of the CHP unit, gas boiler, electric refrigeration, P2G, and CCS equipment are 80.2%, 56.1%, 55.4%, 56.2%, and 60.9%, respectively, indicating sufficient regulation margins for each device to cope with load fluctuations. Simulation results under three extreme conditions show that the CHP unit is the core equipment for ensuring the economic and low-carbon operation of the system; the energy storage unit can effectively smooth source-load fluctuations, and the gas storage unit can provide emergency gas supply when the gas source supply is interrupted. The research results can provide technical support for the transformation of the energy consumption structure of oilfield joint stations.