孔板流量计对含氮伴生气的适应性分析
Adaptability analysis of orifice plate flowmeters to nitrogen-containing associated gas
浏览(4) 下载(0)
- DOI:
- 作者:
- 王哲,齐春明,赵海英,张惠全,郑攀,梁昌晶
Wang Zhe, Qi Chunming, Zhao Haiying, Zhang Huiquan, Zheng Pan, Liang Changjing
- 作者单位:
- 1. 中国石油华北油田分公司,河北任丘 062552; 2. 华北石油管理局有限公司苏里格勘探开发分公司,内蒙古鄂尔多斯 017300; 3. 河北华北油田友信勘探开发服务有限公司,河北任丘 062552
1. PetroChina Huabei Oilfield Company, Renqiu 062552, China; 2. Suiliugong Exploration and Development Branch, Huabei Petroleum Administration Co., Ltd., Ordos 017300, China; 3. Hebei Huabei Oilfield Youxin Exploration and Development Service Co., Ltd., Renqiu 062552, China
- 关键词:
- 孔板流量计;含氮伴生气;GERG-2008状态方程;数值模拟;适应性分析
orifice plate flowmeter; nitrogen-containing associated gas; GERG-2008 equation of state; numerical simulation; adaptability analysis
- 摘要:
- 注氮气驱油技术可有效提高低渗透油藏采收率,但注入氮气会持续改变地层伴生气的组分,导致井口
及站场孔板流量计计量精度失真。为评估孔板流量计对含氮伴生气的适应性,基于GERG-2008状态方程和
Fluent数值模拟,分析了氮气含量对工况密度、黏度、相对密度系数、超压缩系数、流出系数、压差及可膨胀
性系数等计量参数的影响规律,并分析流量相对误差变化规律。结果表明:相对密度系数、超压缩系数、流出
系数、可膨胀性系数的变化与氮气含量呈负相关,差压和上游取压点静压力的变化与氮气含量呈正相关;计量
相对误差均为正值,且随氮气含量、流速和压力的增加而增大;在温度303.15 K、运行压力1 ~ 3 MPa、氮气
含量(摩尔分数)0% ~ 40%的研究工况范围内,孔板流量计体积计量误差可满足GB/T 18603—2023中天然
气计量C级站场的精度要求;部分低氮气含量、低流速工况可满足A级或B级站场计量精度要求。研究结果可
为含氮伴生气集输过程中的流量计选型与误差修正提供理论依据。
Although nitrogen injection gas flooding technology can effectively enhance the oil recovery of low-permeability reservoirs, the injected nitrogen continuously alters the composition of associated gas, thereby affecting the measurement accuracy of orifice plate flowmeters at wellheads and stations. Based on the GERG-2008 equation of state and Fluent numerical simulation, this paper analyzes both the influence laws of nitrogen content on measurement parameters such as the working condition density, viscosity, relative density coefficient, super-compression coefficient, discharge coefficient, pressure difference, and expansibility coefficient, and the variation laws of flow relative error to evaluate the adaptability of orifice plate flowmeters to nitrogen-containing associated gas. The results show that variations in the relative density coefficient, super-compression coefficient, discharge coefficient, and expansibility coefficient show a negative correlation with nitrogen content, while variations in pressure difference and upstream pressure at the sampling point positively correlate with nitrogen content. The measured relative error remains positive in all test conditions and increases with the rising nitrogen content, flow rate, and pressure. Within the temperature range of 303.15 K, pressure range of 1-3 MPa, and nitrogen molar content of 0%-40%, the measurement error of orifice plate flowmeters can meet the accuracy requirements of Class C stations in GB/T 18603—2023. Some low-nitrogen and low-flow-rate conditions can meet the measurement accuracy requirements of Class A or Class B stations. The research results provide a theoretical basis for the selection of flowmeters and error correction in the gathering and transportation process of nitrogen-containing associated gas.