输气管道防雷设计
Lightning Prevention Design of Gas Transmission Pipeline
浏览(1865) 下载(1)
- DOI:
- 作者:
- 任凤堃
REN Feng-kun
- 作者单位:
- 胜利工程设计咨询有限责任公司, 山东东营 257026
Shengli Engineering Consulting Co.,Ltd.,Dongying 257026,China
- 关键词:
- 天然气长输管道|防雷|接地|保护
long-distance natural gas pipeline|lightning prevention|grounding|protection
- 摘要:
- 文章依据GB 50251-2003《输气管道工程设计规范》、GB 50057-1994《建筑物防雷设计规范》,针对天然气长输直埋管道沿线经过的阀室、各种站场、大型跨越管道的结构特点,提出了详细的防雷防静电措施,以及防雷防静电接地装置材料选用的注意事项。
Based on GB50251—2003 “Design Code for Gas Transmission Pipeline Engineering” and GB50057—1994 “Design Code for Protection of Structures against Lightning”, and according to the structural features of valve chambers, stations and large scale pipeline crossings along the line of natural gas transmission pipeline, the author puts forward detailed measures against lightning and static as well as points for attention in selecting materials of grounding device.2009,s1(s1): 35-38 收稿日期:2009-3-6分类号:TE973 TU895作者简介:任凤堃(1964-),男,工程师,2006年毕业于胜利油田职工大学电力工程专业,现从事油田地面工程电气设计工作。