鲁皖成品油管道的交流干扰排流
AC Interference Current Drainage of Shandong-Anhui Product Pipeline
浏览(1814) 下载(3)
- DOI:
- 作者:
- 王健健
WANG Jian-jian
- 作者单位:
- 胜利工程设计咨询有限责任公司, 山东东营 257026
Shengli Engineering Consulting Co.,Ltd.,Dongying 257026,China
- 关键词:
- 埋地钢质管道|腐蚀防护|杂散电流|干扰|排流
buried steel pipeline|anticorrosion protection|stray current|interference|current drainage
- 摘要:
- 由于鲁皖成品油管道较长,沿途经济活动频繁,大量管段与高压线交叉或平行敷设,受到的干扰腐蚀较为严重。文章介绍了杂散电流对埋地管道的影响、杂散电流干扰的综合测试内容及测试结果。根据交流干扰调查测试的结果,对交流干扰电压大于15V的管段采取措施排流,通过采取钳位式排流和锌合金牺牲阳极排流措施,有效控制了管道的腐蚀,保证了管道安全运行。
Because economic activities along the long Shandong-Anhui Product Pipeline are busy and lots of the pipeline sections have been laid across high tension line or in parallel to it, the interference corrosions are severe. The effect of stray current on buried pipeline and the comprehensive detection methods of stray current are illustrated. Based on the investigation on AC interference, the current drainage measures have been adopted for the pipeline sections with AC interference voltage great than 15 V. By means of clamped type current drainage and zinc alloy sacrificial anode, the pipeline corrosions have been controlled effectively2009,s1(s1): 27-33 收稿日期:2009-3-6分类号:TE985.8作者简介:王健健(1976-),男,山东青岛人,1998年毕业于辽宁工程技术大学腐蚀与防护专业,工程师,现从事国内外陆上及滩海油气田管道、储罐、设备、油气站场等的防腐设计与研究工作。