- 摘要:
- 本文根据JB4730-94压力容器无损检测的有关规定推导出球罐γ源偏心局部曝光的焦距选择公式,并对关键性技术问题进行阐述分析,强调焦距选择的重要性和实际选择方法。
This paper gives the formula of focal setting of eccentricity partial exposure of gamma ray source photographic inspection for spherical tanks according to the specification J134730-94 for instction of pressure vessels, analysises the key technical problems and emphasizes the importance of focal setting.1996 ,4(4): 41-43 收稿日期:1996-1-5分类号:TE972