- 摘要:
- 塔器设备和钢结构安装时,地脚螺栓的预紧力必须控制在一定范围内,但设备安装、试车后螺栓应力的初松弛,使地脚螺栓的预紧力不可能保持不变,因而将给设备运行带来隐患。为此在全面考虑预紧力影响因素的基础上,归纳提出塔器设备地脚螺栓预紧力设定和控制的定量依据,并进行了分析探讨。
Prestress of anchor bolt must be controlled in a certain range when tower equipment andsteel structures are installed. Prestress of anchor bolt can be changed because of the initial looseof bolt after mounting the equipment so that a hidden perils would be existed in equipment opera-tion. On the basis of prestress affecting factors in overall considerations,the setting and control-ling of the prestress of anchor bolt for tower equipment are enumerated,and theoretical analyzingand approaching are also made.1997,2(2): 14-21 收稿日期:1997-9-2参考文献:
1 TJ231(-)-75机械设备安装工程施工及验收规范·通用规定
2 YBJ201-83冶金机械设备安装工程施工及验收规范·通用规定
3 HGJ203-83化工机器安装工程施工及验收规范·通用规定
4 [苏」H.E 柳德柯夫斯基,B. I1.沙斯图克,刘文亮译.设备固定到基础上的先进方法.中国建筑工业出版社,1979
5 卜炎.螺纹联结设计与计算.高等教育出版社,1995
6 徐濒主编.机械设计手册(第3卷).机械工业出版社,1991
7 [日]机械技术手册(上册).机械工业出版社,1984
8 〔德]G.尼曼.机械零件(第一卷).机械工业出版社,1985