燃气锅炉对流室基础渗水原因与处理
Causes and Treatment to Water Seepage on Foundation for the Convection Chamber of A Gas-burning Boiler
浏览(1708) 下载(1)
- DOI:
- 作者:
- 岳志宏
Yue Zhihong
- 作者单位:
- 长庆油田油建工程处 745115 甘肃省庆阳县
- 关键词:
- 天然气;锅炉;基础-泄漏;分析;处理
Natural gas;Boiler;Foundation;Leakage;Analysis;Disposal
- 摘要:
- 分析燃气锅炉基础渗水冒泡原因,制定处理方案,实施后锅炉负荷调整灵活、效果很好,消除了以天然气为燃料的锅炉运行中的隐患。
The causes of water seepage and bubbles appeared on foundation for the convection chamber of a gas burning boiler was analyzed, and treatment measures to these problems were established which make the adjustment to boiler load flexible and are effective, eliminating the risk potential for the boiler.2000,4(4): 47-47 收稿日期:1999-8-23