- 摘要:
- 根据现行相关规范对爆炸和火灾危险场所的等级划分,在燃气锅炉房采用非防爆电器设备是符合现行设计规范的,锅炉房选用非防爆型水泵及其他非防爆设备是适宜的。燃气锅炉房应采取相应的安全措施,同时,应建立完善的安全制度、强化运行管理和维护。
According to the classification of dangerous sites of explosion and fire from current related codes, use of non-explosion-proof electrical apparatus in gas boiler room is in accordance with the current design codes, and use of non-explosion-proof pumps or other non-explosion-proof devices in boiler room is also suitable. Meanwhile, the corresponding safety measures should be adopted and the perfect safety system should be established, and the operation management and maintenance should be enhanced.2010,S1(S1): 76-77 收稿日期:2010-10-25分类号:TE44作者简介:周长才(1967-),男,高级工程师,注册公用设备工程师,注册一级建造师,1989年毕业于西北工业大学,现从事设计管理工作参考文献:
[1] 曾彦,黄萍. 燃气锅炉房的电气防爆设计[J]. 黑龙江科技信息,2005,(25):37-37