西气东输二线西段站场的降阻材料选择
Grounding Resistance Reducing Material Selection for Stations of West Section of Second West to East Gas Pipeline
浏览(1989) 下载(1)
- DOI:
- 作者:
- 董昭旸, 王新坤, 李岩
DONG Zhao-yang, WANG Xin-kun, LI Yan
- 作者单位:
- 中国石油天然气管道局设计院
Design Institute of China Petroleum Pipeline Bureau, Langfang 065000, China
- 关键词:
- 输气站场;接地电阻;降阻材料
gas station;grounding resistance;resistance reducing material;electrolytic ion grounding electrode;resistance agent;grounding modular plate
- 摘要:
- 输气站场对接地电阻的要求很高,对于某些土壤电阻率较高及受到地网范围限制的独立接地,采用常规的接地装置往往很难达到预期的接地电阻要求。文章详细分析了常用的几种降阻材料的构成、降阻原理、使用效果和特点,重点介绍了在西气东输二线西段站场应用的电解离子接地极的特点和使用效果。
Gas station needs a strict requirement for grounding resistance. If some independent groundings in high earth resistance area and limited earth mat area adopt traditional materials and devices, the grounding resistances can't reach expectative values. The composition, working principle, application results and characteristics of several resistance reducing materials for grounding are analyzed in detail. The characteristics and application results of electrolytic ion grounding electrode used at stations of west section of Second West to East Gas Pipeline are especially introduced.2010,S1(S1): 59-61 收稿日期:2010-10-25分类号:TE988作者简介:董昭旸(1981-),男,河北沧州人,工程师,2004年毕业后一直从事管道工程的电力设计工作参考文献:
[1] 何金良,曾嵘.电力系统接地技术[M]. 北京:科学出版社,2007