- 石油化工生产装置大多是通过火炬燃烧排放易燃易爆气体或通过放空管将易爆气体直接排入大气中。文章分析了火炬系统和放空管的火灾危险因素,并从火炬的布置、高度、排放能力、自动监控装置以及放空管的气体排放浓度、安装位置、安全装置等方面,重点论述了火炬系统和放空管的消防安全设计要点。
Flammable gas produced from petrochemical facility is discharged mostly by torching or directly into air through vent pipe.This paper analyzes the fire danger factors for torching system and vent pipe,and addresses the key design matters of deployment,height,discharging capacity and automatic monitoring device of torch as well as the discharging gas concentration,installation position and security device of the vent pipe.2006,6(6): 16-19 收稿日期:2006-1-16分类号:TE687作者简介:黄汉京(1956- ),男,湖南郴州人,1997 年毕业于河南教育学院,现为郑州经济管理干部学院环境工程系教师。参考文献:
[1] GB 50160-1992,石油化工企业设计防火规范[S].
[2] 惠中玉.工业企业防火工程[M]. 北京:中国人民公安大学出版社,1994.
[3] 惠中玉.现代消防管理手册[M].北京:企业管理出版社,1996.
[4] [苏]M.B.别斯恰斯特诺夫.化工生产中事故的预防[M].北京:化学工业出版社,1987.