温度变化对钢质管道水压试验的影响
Effect of Temperature Variation on Hydraulic Pressure Test of Steel Pipelines
浏览(2223) 下载(8)
- DOI:
- 作者:
- 潘永东1, 张洪元2
PAN Yong-dong1, Zhang Hongyuan2
- 作者单位:
- 1. 中国石油华北油田公司, 河北任丘 062552;
2. 中国石油集团工程技术研究院, 天津 300451
CNPC Huabei Oilfield Company, Renqiu, 062552, China
- 关键词:
- 钢质管道;水压试验;温度影响;定量计算
steel pipeline hydraulic pressure;test temperature;effect quantitative;calculation
- 摘要:
- 水压试验作为检验管道强度及严密性的一道关键工序,在管道建设中非常重要。但由于水的力学特性复杂,其温度变化对水压试验带来的影响尤为突出。文章根据弹性力学和水力学理论,通过分析水压试验机理,阐述了温度变化对管道水压试验的影响,建立了定量计算方法,为管道水压试验质量评定工作提供了科学依据,大大方便了对水压试验结果的判定,并举例对该计算方法进行了验证
Based on the elastic and hydraulic theories along with the analysis on hydraulic pressure test mechanism, this paper addresses the effect of temperature variation on hydraulic pressure test and establishes quantitative calculation method which offers a scientific basis of quality assessment for pipeline hydraulic pressure test, and facilities the judgment for test results. A practical example is taken to verify the calculation method.2006,5(5): 10-12 收稿日期:2006-3-14分类号:TE973.6作者简介:潘永东(1962- ),男,江苏南京人,高级工程师,1983 年毕业于华东石油学院机械系化工机械专业,国家注册安全工程师,国家一级建造师,长期从事油气田工程建设技术及安全生产管理工作。参考文献:
[1] SY0422-1997,油田集输管道施工及验收规范[S].
[2] GB/T 16805-1997,液体石油管道压力试验[S].
[3] 曹伟立.水力学[M].北京:石油工业出版社,1989.5-6.
[4] SY0401-1998,输油输气管道线路工程施工及验收规范[S].