- 摘要:
- 对已使用14年,目前发生腰鼓变形的焦炭塔的筒体材质进行了金相检验,发现其珠光体球化达到4级,材质老化程度较大;进行了硬度、厚度、应力、温度测试和应力、最大允许操作压力的校核,确认焦炭塔在厚度和强度方面是安全的,最后判定此焦炭塔的安全等级可以评定为4级,并建议要严格控制焦炭塔的实际使用温度,定期进行现场金相检验,掌握筒体组织珠光体球化的程度,以保证设备的安全运行。
Metallographic test of the specimen material taken from a deformed wall of a coking tower was performed. Its pearlite spheroidization was found to rank fourth grade, the material aging was severe. Through testing hardness, thickness, stress and temperature as well as checking stress and maximum allowed operating pressure, it was concluded that the coking tower was safe concerning strength and thickness. Finally, the safety of the coking tower was judged to be fourth grade.2006,2(2): 47-50 收稿日期:2005-9-29分类号:TE962作者简介:陈涛(1981-),男,湖南衡阳人,辽宁石油化工大学在读硕士.参考文献:
[1]曾超.焦炭塔材料球化程度计算模型研究[J].压力容器,2004,(11):5-8.
[2]崔忠昕.金属材料学及热处理[M].北京:机械工业出版社,1995,10.
[3]DL/T764-1999,火电厂用20号钢珠光体球化评级标准[S].
[4]李智超.20G钢魏氏组织韧性及微观形貌研究[J].物理测试,2003,(5):7-10.
[5]赵登志,宋静.温度对12Cr1MoV钢关于珠光体球化及力学性能的影响[J].电站系统工程,2002,18(3):58-59.
[6]李禄臣,高宝林.12Cr1MoV钢不同球化级别的高温性能及寿命[J].河北电力技术,1997,16(4):40-43.
[7]胡华勇.10CrMo910原始组织异常原因分析及安全性评价[J].广西电力技术,2001,(2):13-15.