阴极保护系统输出电流和开路电位异常的故障分析
Analysis and Solution for Current Overload and Potential Reversion Happened in Cathodic Protection System
浏览(2381) 下载(1)
- DOI:
- 作者:
- 郭超1, 马晓东1, 刘威1, 阎益龙1, 左禹2
GUO Chao1, MA Xiao-dong1, LIU Wei1, YAN Yi-long1, ZUO Yu2
- 作者单位:
- 1. 中国石油工程建设公司, 北京 100011;
2. 北京化工大学材料科学与工程学院, 北京 100029
China Petroleum Engineering and Construction Corp., Beijing 100011, China
- 关键词:
- 阴极保护;故障;修复;外加电流;开路电位;极性逆转
cathodic protection;malfunction;repair;impressed current;open-circuit potential;polarity reversion
- 摘要:
- 阿尔及利亚凝析油项目的一座储罐外加电流阴极保护系统出现故障:外加电流阴极保护系统输出电流过大和开路电位出现异常。通过采用多种手段对该故障进行测试分析,最终确定由于阳极电缆的罐外部分与地短接,并通过大地与罐底阴极形成回路从而引起系统不能正常运行。经排除故障,系统恢复了正常工作。
A malfunction happened in an impressed current cathodic protection system for tank bottom in an Algeria condensate oil project is analyzed. The possible reasons which may cause large current output and abnormal potential are investigated. Field testing is carried out and the obtained data are analyzed to verify the reason. It is found that the malfunction is due to the short circuit between an anodic cable and the tank bottom, and then the malfunction is successfully eliminated.2009,06(06): 62-64 收稿日期:2009-2-19分类号:TG174.41作者简介:郭超(1978-),男,山东威海人,工程师,2007年毕业于北京化工大学材料学专业,博士,现从事防腐蚀设计及研发工作。参考文献:
[1] 汪文兵,龙晋明,郭忠诚. 钛基金属氧化物涂层电极的研究进展
[J].电镀与涂饰,2006,25(7):46-48.
[2] 郭超,左禹,翟克刚,等. 混合金属氧化物涂层在酸碱和中性环境中的电化学行为[J]. 材料保护,2008,41(8):9-12.
[3] Hu J M,Meng H M,Zhang J Q, et al. Degradation mechanism of longservice life Ti/IrO2 -Ta2O5 oxide anodes in sulphuric acid [J].Corrosion Science, 2002, 44(8):1 655-1 668.
[4] 王廷勇,许立坤. 均匀设计在金属氧化物阳极材料研究中的应用
[J]. 海洋科学,2005,29(7):8-11.