特殊条件下的球罐γ射线全景曝光
Gamma Rays Panoramic Exposure of Spherical Tank in Special Condition
浏览(2132) 下载(2)
- DOI:
- 作者:
- 陈志慧
Chen Zhihui
- 作者单位:
- 福建省锅炉压力容器检验所, 福建福州 350003
Fujian Institute of Boiler and Pressure Vessel Inspection, Fuzhou 350003, China
- 关键词:
- 球罐;γ射线检测;全景曝光;放射源活度
spherical tank;gamma rays(γ-rays);panoramic exposure;activity of radiation source
- 摘要:
- 文章阐述了对2000m3球罐使用两种不同的γ放射源(共计4根),在偏心的条件下进行全景曝光的检测过程。检测结果表明:底片的曝光质量良好,能够反映球罐的焊接质量。这次全景曝光检测是非标检测,但却获得了成功,这对球罐在特殊条件下进行非标检测,具有一定的参考价值。这一经验也可为500m3以下的钢制球罐的全景曝光检测提供参考。
Panoramic exposure for a 2 000 m3 spherical-tank has been taken by using two kinds of gamma rays from 4 gamma sources in eccentricity condition. The inspection results showed that film exposure quality was very well to reflect welding quality of the spherical tank. This non-standard inspection was successful and provided experience for similar tank inspection, including the steel spherical tanks of less than 500 m3 storage capacity2009,03(03): 69-70 收稿日期:2008-9-11分类号:TE969;TG115.28作者简介:陈志慧(1968-),男,湖北天门人,高级工程师,1990年毕业于江汉石油学院电子仪器专业,现从事无损检测工作。参考文献:
[1] 强天鹏. 射线检测[M].云南:云南科技出版社,2001.
[2] JB/T 4730.1~4730.6-2005,承压设备无损检测[S].