涩北首站工艺系统存在的问题及对策
Problems Existing in Process System at Sebei Initial Station and Countermeasures
浏览(2098) 下载(1)
- DOI:
- 作者:
- 尹广增, 赵国辉, 黄显中
YIN Guang-zeng, ZHAO Guo-hui, HUANG Xian-zhong
- 作者单位:
- 中国石油管道兰州输气分公司,甘肃兰州 730070
CPP Lanzhou Gas Transportation Company, Lanzhou 730070, China
- 关键词:
- 输气管道;首站;工艺系统;改造
gas transmission pipeline;initial station;process system;reformation
- 摘要:
- 涩北首站运行的1#压缩机机组因干气密封过滤器差压高报警停机,其原因是气田来气含水量突然大量增加,致使机组自动保护停机,造成压缩机干气密封损坏。为此对该工艺系统存在的问题进行了分析,并提出了改进措施和技术改造实施中应注意的问题。
Because the water content in gas produced from the gas field suddenly increased and produced high differential gas pressure in the dry gas filter of the compressor so as to damage its gas seal, No.1 com-pressor set at Sebei initial station alarmed and stopped. Then the problems in the process system were ana- lyzed. The improving measures and matters for attention in technical reformation of the system were put for- ward.2009,2(2): 25-26 收稿日期:2008-4-11分类号:TE974作者简介:尹广增(1975-),男,河北邢台人,工程师,1998年毕业于重庆石油高等专科学校内燃机制造与雏修专业,现从事压气站管理工作.